Plugin: go.d.plugin Module: litespeed
Examine Litespeed metrics for insights into web server operations. Analyze request rates, response times, and error rates for efficient web service delivery.
The collector uses the statistics under /tmp/lshttpd to gather the metrics.
This collector is supported on all platforms.
This collector only supports collecting metrics from a single instance of this integration.
If no configuration is present, the collector will attempt to read files under /tmp/lshttpd/.
The default configuration for this integration does not impose any limits on data collection.
The default configuration for this integration is not expected to impose a significant performance impact on the system.
No action required.
The configuration file name for this integration is go.d/litespeed.conf
.
You can edit the configuration file using the edit-config
script from the
Netdata config directory.
cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/litespeed.conf
The following options can be defined globally: update_every, autodetection_retry.
Name | Description | Default | Required |
---|---|---|---|
update_every | Data collection frequency. | 10 | no |
autodetection_retry | Sets the job re-check interval in seconds. | 0 | no |
reports_dir | Directory containing Litespeed’s real-time statistics files. | /tmp/lshttpd/ | no |
Change the path for the litespeed stats files
local:
name: 'local'
path: '/tmp/lshttpd'
Metrics grouped by scope.
The scope defines the instance that the metric belongs to. An instance is uniquely identified by a set of labels.
These metrics refer to the entire monitored application.
This scope has no labels.
Metrics:
Metric | Dimensions | Unit |
---|---|---|
litespeed.requests | requests | requests/s |
litespeed.requests_processing | processing | requests |
litespeed.net_throughput | in, out | kilobits/s |
litespeed.net_ssl_throughput | in, out | kilobits/s |
litespeed.connections | free, used | conns |
litespeed.ssl_connections | free, used | conns |
litespeed.public_cache | hits | hits/s |
litespeed.private_cache | hits | hits/s |
litespeed.static | hits | hits/s |
There are no alerts configured by default for this integration.
Important: Debug mode is not supported for data collection jobs created via the UI using the Dyncfg feature.
To troubleshoot issues with the litespeed
collector, run the go.d.plugin
with the debug option enabled. The output
should give you clues as to why the collector isn’t working.
Navigate to the plugins.d
directory, usually at /usr/libexec/netdata/plugins.d/
. If that’s not the case on
your system, open netdata.conf
and look for the plugins
setting under [directories]
.
cd /usr/libexec/netdata/plugins.d/
Switch to the netdata
user.
sudo -u netdata -s
Run the go.d.plugin
to debug the collector:
./go.d.plugin -d -m litespeed
If you’re encountering problems with the litespeed
collector, follow these steps to retrieve logs and identify potential issues:
Use the following command to view logs generated since the last Netdata service restart:
journalctl _SYSTEMD_INVOCATION_ID="$(systemctl show --value --property=InvocationID netdata)" --namespace=netdata --grep litespeed
Locate the collector log file, typically at /var/log/netdata/collector.log
, and use grep
to filter for collector’s name:
grep litespeed /var/log/netdata/collector.log
Note: This method shows logs from all restarts. Focus on the latest entries for troubleshooting current issues.
If your Netdata runs in a Docker container named “netdata” (replace if different), use this command:
docker logs netdata 2>&1 | grep litespeed
Want a personalised demo of Netdata for your use case?